COMBINER BOX 18 WAY
12.00% OFF

COMBINER BOX 18 WAY

Ksh 4,000.00

Ksh 4,545.45
Description

1. Function & Purpose:

This combiner box acts as a primary DC power distribution hub in massive solar arrays. Its core functions extend beyond simple combining:

Mass String Aggregation: Parallelizes eighteen independent PV source circuits into a single, high-amperage circuit for efficient long-distance transmission to central inverters.

Comprehensive Fault Protection: Provides mandatory individual overcurrent protection (fusing) for each string against reverse currents from other strings.

Advanced System Monitoring: Equipped for precise, real-time string-level performance monitoring, fault detection, and data logging.

Surge Suppression: Protects the entire consolidated circuit from lightning-induced and switching overvoltages.

Main Disconnection: Features a high-capacity main disconnect for safely isolating the entire combiner output for maintenance.

2. Key Specifications Decoded:

18 WAY: This specifies an ultra-high input capacity, designed to manage the inputs from eighteen separate solar strings. It contains eighteen individual fuse holders and associated termination points.

3. Key Components Inside an 18-Way Combiner Box:

Fuse Holders (x18): Individual fuse holders for each string, designed for 1500VDC PV fuses (typically 15A, 20A, or 32A). Fusing is a non-negotiable safety requirement for this many parallel strings.

High-Current Busbars: Heavy-duty, often silver-plated copper busbars with significant cross-sectional area, engineered to handle the continuous combined current from eighteen strings (e.g., 18 strings × 12A = 216A+)

without overheating.

Main DC Disconnect: A 1500VDC-rated, load-break isolator switch or a Molded Case Circuit Breaker (MCCB) rated for the full combined current (often 250A-400A), used to disconnect the entire output.

Surge Protective Device (SPD): One or more heavy-duty Type 2 (or Type 1+2) SPDs to protect against lightning and switching surges.

Monitoring System: Integrated current transformers (CTs) or sensors for each of the eighteen strings, connected to a data logger with communication ports (e.g., RS485, Ethernet, Fiber) for integration into a Plant SCADA system.

Grounding System: Large, dedicated grounding bars for all equipment grounding conductors (EGCs) and system grounding.

Thermal Management: May include active cooling (e.g., fans) or passive heat sinks to manage the significant thermal load generated by the busbars and terminations under full power.

4. How It Is Used:

Eighteen separate strings from a large section of the solar farm are wired to the combiner box.

Each string's positive conductor is landed on its own fused input.

Each string's negative conductor is terminated on a common, high-capacity negative busbar.

The large combined output (using very large gauge cable, e.g., 250-500 kcmil) is run to a central inverter rated for MW-scale power.

5. Key Advantages:

Extreme Infrastructure Efficiency: Dramatically reduces the quantity and cost of wiring, conduit, and trenching by combining 36 conductors (18 +/- pairs) into just two output conductors.

Centralized Control: Provides a single point for protection, monitoring, and maintenance for a massive segment of the PV array (often representing 500kW - 1MW+ of capacity).

Data-Rich Diagnostics: Enables granular, real-time analysis of each string's health and performance, which is critical for maximizing uptime and energy yield in a multi-million dollar asset.

Scalability: Serves as a fundamental building block for utility-scale solar plants exceeding several megawatts.

6. Critical Installation Notes:

Mandatory Fusing: Every single one of the eighteen strings must be individually fused. The potential reverse fault current from seventeen healthy strings is catastrophic without proper protection.

Professional Engineering Required: The entire system must be engineered for maximum fault current (available short-circuit current). Component ratings (fuse interrupt rating, busbar bracing) must exceed this value.

Enclosure Rating: Must be NEMA 4X / IP66 or higher, designed for harsh, continuous outdoor exposure, often with UV-stabilized and corrosion-resistant materials.

Torque Management: All terminations must be torqued to the manufacturer's specifications with a calibrated tool. Loose connections at these current levels will fail catastrophically.

Ventilation: Thermal management is critical. The installation location must allow for adequate airflow if the box relies on passive cooling.

Specifications

Related Products

20.00% OFF
AVS 30
AVS 30

Ksh 5,800.00

Ksh 7,250.00

11.00% OFF
Change Over Switch
Change Over Switch

Ksh 4,500.00

Ksh 5,056.18

7.00% OFF
 Inverter monitor  Wi-Fi Module
Inverter monitor Wi-Fi Module

Ksh 2,500.00

Ksh 2,688.17

6MM 2000 VDC, 100M ROLL
6MM 2000 VDC, 100M ROLL

Ksh 170.00

Chat with us on WhatsApp